TM 9-2320-361-24-2
FIELD MAINTENANCE INSTRUCTIONS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
GALLON METER REPLACEMENT (M49A2C)
REMOVAL AND INSTALLATION
INITIAL SETUP:
Applicable Models
Equipment Condition
M49A2C
Parking brake set and wheels chocked
(TM 9-2320-361-10).
Materials/Parts
Battery ground cable disconnected
(WP 0126 00).
Three lockwashers (item 195, WP 0470 00)
Meter outlet tube removed (WP 0282 00).
Globe valve removed (WP 0272 00).
Meter-to-filter tube removed (WP 0275 00).
REMOVAL
1.
Remove three screws (4), lockwashers (5), and gallon meter (1) from shelf (6). Discard lockwashers (5).
2.
Remove pipe (3) from elbow (2) and elbow (2) from gallon meter (1).
INSTALLATION
NOTE
Clean all male pipe threads and wrap with antiseize tape before
installation.
1.
Install
elbow (2) on gallon meter (1) and pipe (3) on elbow (2).
2.
Install
gallon meter (1) on shelf (6) with three screws (4) and new lockwashers (5).
3.
Install
meter-to-filter tube (WP 0275 00).
4.
Install
globe valve (WP 0272 00).
5.
Install
meter outlet tube (WP 0282 00).
6.
Connect battery ground cable (WP 0126 00).
7.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
1
2
6
5
4
3
END OF WORK PACKAGE
0276 00-1/2 blank
|