TM 9-2320-361-24-1
0079 00
PERSONNEL HEATER INLET AND OUTLET HOSE REPLACEMENT (Contd)
INSTALLATION (Contd)
CAUTION
Type 1, ethylene glycol (green) and Type 2, propylene glycol
(purple), should never be mixed due to their differences in
toxic properties. Failure to comply may result in damage to
equipment.
Using antifreeze without mixing it with water can cause high
operating temperatures, blockage of cooling system passages,
and damage to water pump seals.
NOTE
Type 1 antifreeze is an ethylene glocol based coolant, green in
color, and is the only authorized antifreeze for military vehicles.
Type 1 can be added to factory filled pink coolant. When it
becomes necessary to flush factory coolant, Type 1, ethylene
glycol will be used. When mixing Type 1 antifreeze with water,
distilled water is recommended. Tap water should only be used
in emergency situations.
4.
Check level of antifreeze and add as necessary.
5.
Connect battery ground cable (WP 0126 00).
6.
Lower and secure hood (TM 9-2320-361-10).
7.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
1
3
4
2
5
1
6
10
9
4
7
4
8
END OF WORK PACKAGE