Page Title: PERSONNEL HEATER INLET AND OUTLET HOSE REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-361-24-1
0079 00
PERSONNEL HEATER INLET AND OUTLET HOSE REPLACEMENT (Contd)
REMOVAL
1.
Remove locknut (9), screw (7), two clamps (1), inlet hose (3), and outlet hose (5) from bracket (2).
Discard locknut (9).
WARNING
Do not remove inlet hose or outlet hose when engine is hot.
Steam or hot coolant under pressure may cause injury to
personnel.
Accidental or intentional introduction of liquid contaminants
into the environment is a violation of state, federal, and
military regulations. Refer to Army POL (WP 0001 00) for
information concerning storage, use, and disposal of these
liquids. Failure to do so may result in damage to environment
and health of personnel.
NOTE
Use a drain pan to capture any draining coolant. Dispose of
fluids in accordance with local policy and ordinances. Ensure all
spills are cleaned up.
2.
Loosen four clamps (4) and remove inlet hose (3) and outlet hose (5) from heater (6), water
pump (8), and intake manifold (10).
3.
Remove four clamps (4) and two clamps (1) from inlet hose (3) and outlet hose (5).
INSTALLATION
1.
Install two clamps (1) and four clamps (4) on inlet hose (3) and outlet hose (5). Do not tighten
clamps (4).
2.
Install inlet hose (3) and outlet hose (5) on heater (6), water pump (8), and intake manifold (10).
Tighten four clamps (4).
3.
Install two clamps (1), inlet hose (3), and outlet hose (5) on bracket (2) with screw (7), and new
locknut (9).
0079 00-2