BATTERY AND CHARGING SYSTEM TROUBLESHOOTING (Contd)
VOLTAGE
REGULATOR
100-AMP
C
A
2
6
POS
STARTER
12-VOLT
2
14
BATTERY
214
4
C
1
3
+ FLD
FLD
E
D
STARTER
B
MOTOR
68
D
C
NEG
SLAVE
RECEPTACLE
STARTER
START
SWITCH
74B
74A
74
B
F
+24V TO FLD
+24V TO FLD
27
1
55
+1.5V TO 24V
B
POWER
27
ACCESSORY
D
SWITCH
C
11
10
A
ADJUSTABLE
E
B
10
11
11
OUT
VOLTAGE
10
IN
AMPLIFIER
15
HORN
CIRCUIT
BREAKER
25
Table 4. Charging System (100 Amp) Troubleshooting Procedure.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
If STE/ICE-R is available, perform
1. NO ALTERNATOR
NG 50 Charging Circuit Tests
OUTPUT
Test 1. Check for loose or missing
1. Adjust loose belts (WP 0084 00).
belts.
2. Replace missing belts
|