Click here to make tpub.com your Home Page

Page Title: Table 21. Personnel Fuel Burning Heater Troubleshooting Procedures - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-361-24-1
0006 00
MECHANICAL SYSTEMS TROUBLESHOOTING - UNIT (Contd)
Table 21. Personnel Fuel Burning Heater Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 4. Check for input power at
1. HEATER WILL NOT
fuel pump.
OPERATE IN HIGH OR
LOW POSITION
1. Set multimeter to range
(Contd)
that will measure 24 VDC.
2. Disconnect lead 25 at fuel
pump.
3. Touch multimeter positive
lead to contact end of lead
25.
4. Touch multimeter negative
1. If voltage is present, replace
lead to frame ground.
personnel fuel burning heater
Voltage should be present.
(WP 0351 00).
2. If voltage is not present, repair or
replace lead 25 (WP 0090 00).
Test 5. Check fuel pump for proper
Refer to WP 0006 00, table 21,
operation.
malfunction 2.
Test 6. Check for power input at
personnel heater.
1. Set multimeter to voltage
that will measure 24 VDC.
2. Disconnect harness
connector at personnel
heater.
3. Set heater control switch.
4. Touch multimeter positive
lead to pin A of harness
connector.
5. Touch multimeter negative
lead to frame ground.
6. Repeat steps 4 and 5 for
1. If voltage is present, replace
pins B, C, and D. Voltage
personnel heater (WP 0351 00).
should be present at all
pins tested.
2. If voltage is not present at one or
more pins, repair or replace
0006 00-27

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business