TM 9-2320-361-24-1
0006 00
MECHANICAL SYSTEMS TROUBLESHOOTING - UNIT (Contd)
Table 21. Personnel Fuel Burning Heater Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 4. Check for input power at
1. HEATER WILL NOT
fuel pump.
OPERATE IN HIGH OR
LOW POSITION
1. Set multimeter to range
(Contd)
that will measure 24 VDC.
2. Disconnect lead 25 at fuel
pump.
3. Touch multimeter positive
lead to contact end of lead
25.
4. Touch multimeter negative
1. If voltage is present, replace
lead to frame ground.
personnel fuel burning heater
Voltage should be present.
(WP 0351 00).
2. If voltage is not present, repair or
replace lead 25 (WP 0090 00).
Test 5. Check fuel pump for proper
Refer to WP 0006 00, table 21,
operation.
malfunction 2.
Test 6. Check for power input at
personnel heater.
1. Set multimeter to voltage
that will measure 24 VDC.
2. Disconnect harness
connector at personnel
heater.
3. Set heater control switch.
4. Touch multimeter positive
lead to pin A of harness
connector.
5. Touch multimeter negative
lead to frame ground.
6. Repeat steps 4 and 5 for
1. If voltage is present, replace
pins B, C, and D. Voltage
personnel heater (WP 0351 00).
should be present at all
pins tested.
2. If voltage is not present at one or
more pins, repair or replace
0006 00-27
|