21-18.  SLAVE RECEPTACLE KIT INSTALLATION. Install kit using instructions that
come with kit.
Section III.
DEEP WATER FORDING KIT
21-19.  DEEP WATER FORDING KIT INSTALLATION. Install deep water fording kit
using instructions that come with the kit.
DEEP WATER FORDING KIT OPERATING TESTS .
TOOLS :
No special tools required
SUPPLIES :
Soapy water
PERSONNEL : Two
EQUIPMENT CONDITION :
Truck parked, handbrake set, transmission in neutral
position, fording control handle pulled out, engine off.
Preliminary Procedure. Open hood.
Refer to Engine Equipment Items
Maintenance, TM 9-2320-209-10.
b.
Intake Operating Test.
WARNING
If engine is running indoors, make sure that
truck is in a well-ventilated area and exhaust
fumes are vented directly outdoors. Breathing
in of fumes will cause injury to personnel.
1.
Take out flywheel housing drain plug (1) and put it into drain port hole (2).
2.
Start engine.
Refer to General Operating Procedures, TM 9-2320-209-10.