TM 9-2320-209-34-2-3
FRAME 9
NOTE
Use container (3) to catch overflow for this test.
Hold fuel outlet (1) of fuel control valve (2) over overflow container (3).
1.
Make sure HI-LO switch (4) is in LO position. Flip control switch (5) to
2.
RUN position. Fuel pump should be pumping.
Flip HI-LO switch (4) to HI. Let fuel flow into overflow container (3) for
3.
a few seconds. Flip HI-LO switch (4) to LO position.
4.
Look at fuel outlet (1) for one minute. One or two drops may form, but fuel
flow must be completely stopped.
5.
Do steps 1 through 4 again.
Flip control switch (5) to OFF position.
6.
If fuel flow does not stop completely when HI-LO switch (4) is flipped to
LO position, get new fuel control valve (2).
IF FUEL CONTROL VALVE PASSES TEST, GO TO FRAME 10.
IF FUEL CONTROL VALVE FAILS TEST, GET A NEW ONE. END OF TASK