TM 9-2320-209-34-2-3
FRAME 2
1.
Take off wiring harness (1) from electrical connector (2).
2.
Take off fuel supply line (3) from fuel inlet fitting (4). Take off exhaust
pipe (5).
WARNING
Coolant may be hot. Use caution when working near hot
coolant. Severe burns could result.
Take off coolant outlet hose (6) and coolant inlet hose (7).
3.
4.
Take off heater (8) from test stand (9).
NOTE
Follow-on Maintenance Action Required:
Replace power plant heater. Refer to para 21-6.
END OF TASK
21-15
|