Page Title: POWERPLANT HEATER TEST - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-34-2-3
FRAME 2
1.
Take off wiring harness (1) from electrical connector (2).
2.
Take off fuel supply line (3) from fuel inlet fitting (4). Take off exhaust
pipe (5).
WARNING
Coolant may be hot.  Use caution when working near hot
coolant.  Severe burns could result.
Take off coolant outlet hose (6) and coolant inlet hose (7).
3.
4.
Take off heater (8) from test stand (9).
NOTE
Follow-on Maintenance Action Required:
Replace power plant heater. Refer to para 21-6.
END OF TASK
21-15