(6) Stopping test.
FRAME 1
1.
Put control switch (1) in OFF position, put HI-LO switch (2) in LO position.
Take off ground lead (3) from minus (-) battery terminal (4). Take off
power supply lead (5) from plus (+) battery terminal (6).
2.
Put on and cover plate (7).
Refer to para 21-6e, frame 7.
WARNING
Coolant may be hot.  Use caution when working near hot
coolant.  Severe burns could result.
3.
Drain coolant from coolant container (8).
GO TO FRAME 2