|
|
TM 9-2320-209-34-2-3
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in well-
ventilated places. Failure to do this may result
in injury to personnel and damage to equipment.
Clean all metal parts with dry cleaning solvent. Dry with clean
Cleaning.
c.
rags.
d.
Inspection and Repair.
FRAME 1
1.
Check that lamp support bracket (1) is not bent, dented, torn or cracked.
To straighten bent or dented parts, refer to TM 10-450. To weld tears or
cracks, refer to TM 9-237. If more repair is needed, get new parts.
Check that all threaded parts are not stripped or cross threaded.
2.
END OF TASK
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |