FRAME 2
NOTE
Readings must be within limits given in table 17-6.
If readings are not within given limits, throw away
part and get a new one.
1.  Measure fit of bearing (1) on shaft (2).
GO TO FRAME 3
Table 17-6. Power Leveler Assembly Wear Limits
Size and Fit
Index
of New Parts
Wear Limit
Number
Item /Point of Measurement
(inches)
(inches)
1 and 2
Fit of bearing on shaft
0.001 to 0.005
None