TM 9-2320-209-34-2-2
c. Cleaning. There are no special cleaning procedures needed. Refer to
cleaning procedures given in Part 1, para 13.
d.
Inspection and Repair.
FRAME 1
Check that three brackets (1), two cams (2), two levers (3), and shafts
1.
(4 and 5) have no cracks, breaks or other damage. If parts are damaged, get
new ones.
2.
Check that fusible link release lever (6), manual release lever (7), clevis (8),
and fusible link (9) have no cracks, breaks or other damage. If parts are
damaged, get new ones.
G O TO FRAME 2
|