TM 9-2320-209-34-2-1
h.
Replacement of Bearing into Housing.
TOOLS: No special tools required
SUPPLIES: Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
Anti-seize compound, white lead, Fed. Spec TT-A-680-B-2
PERSONEL:
One
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in
well-ventilated places. Failure to do this may
result in injury to personnel and damage to
equipment.
1.
Using solvent, clean bore of housing (1).
2.
Coat bore of housing (1) with anti-seize compound.
3.
Put housing (1) in place in arbor press (2).
4.
Place bearing (3) squarely on bore of housing (1).
Put sleeve (4) on outer race (5) of bearing ( 3).
5.
Put steel drive plate (6) on top of sleeve (4).
6.
7.
Push bearing (3) into housing (1).
END OF TASK
|