TM 9-2320-209-34-2-1
FRAME
5
1.
Using bearing preload tester, pn 7950157, (1), wrap cable (2) around through
shaft (3).
Pull on tester (1) until shaft turns. If original bearings are used, reading
2.
should be 4 to 8 pound-inches. If new bearings are used, reading should be
12 to 18 pound-inches.
Take off tester (1).
3.
IF READING IS NOT WITHIN LIMITS GIVEN, GO TO FRAME 6.
IF READING IS WITHIN LIMITS GIVEN, TAKE OUT THROUGH SHAFT (3) (REFER
TO PARA 1O-7c, FRAME 10), THEN GO TO FRAME 7
10-73
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |