TM 9-2320-209-20-3-4
c. Repair.
FRAME 1
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
1. Soak transmission breather (1) in solvent.
2. Using wire brush, brush all dirt from transmission breather (1).
3. Clean passage (2) and make sure valve cap (3) moves freely.
4. Use clean lubricating oil to lubricate transmission breather (1).
END OF TASK
|