|
|
TM 9-2320-209-20-3-4
c.
Cleaning, Inspection, and Repair.
FRAME 1
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
Eye shields must be worn when using compressed air.
Eye injury can occur if eye shields are not used.
1. Clean all parts with solvent.
2. Using compressed air, clean magnet inside of cover (1).
3. Check that cover (1) has no cracks or breaks. If cover is damaged, throw it
away and get a new one.
4. Check that sediment strainer (2) has no cracks, breaks, tears or bends. If
sediment strainer is damaged, throw it away and get a new one.
END OF TASK
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |