TM 9-2320-209-20-3-4
a.
Removal.
FRAME 1
1.
Soldier A
Using allen wrench, loosen two setscrews (1).
2.
Hold pump (2) so it will not fall when soldier A works on it.
Soldier B
3.
Using wrenches, unscrew and take out four screws (3) and nuts
Soldier A
(4).
4.
Hold universal joint (5).
Pull pump (2) out of universal joint (5).
5.
Soldier B
Take universal joint (5) off shaft (6). Using ballpeen hammer and
6.
Soldier A
brass drift, tap out two keys (7).
Put pump (2) back in place, alining hole for one screw (3).
7.
Soldier B
8.
Using wrenches, screw in and tighten one screw (3) and nut (4) to
Soldier A
hold pump (2).
GO TO FRAME 2
|