FRAME 3
CAUTION
Do not overtighten hose fittings when joining hoses.
Finger tighten hose adapters. Using two 1-inch
wrenches, tighten fittings 1/8 turn more.
NOTE
Take off caps from hoses and fittings before putting
on hose fittings.
1.
Using 1-inch wrench, screw on and tighten control valve supply hose
assembly (1) to tee pipe (2) as tagged. Take off tags.
2.
Using 1-inch wrench, screw on and tighten pump supply hose assembly (3)
to tee pipe with check valve (4) as tagged. Take off tags.
3.
Using 7/8-inch wrench, screw on and tighten pump bypass hose assembly (5)
to tee pipe with check valve (4) and tee-pipe (2).
GO TO FRAME 4