TM
9-2320-209-20-3-3
c.
Replacement.
FRAME 1
1.
Put discharge valve operating lever assembly (1) in place, feeding two
cables (2) through holes in bracket (3).
2.
Using 7/16-inch wrenches, screw in and tighten six bolts (4) and six nuts (5).
3.
Using 5/8-inch open end wrench, hold two fitting nuts (6). Using 3/4-inch
wrench, screw on and tighten two coupling nuts (7).