TM
9-2320-209-20-3-3
M49A2C).
TOOLS:
9/16-inch wrench (2)
Scraper
SUPPLIES: Manhole cover gasket
Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
Rags
PERSONNEL:
One
Truck parked, engine off, handbrake set.
EQUIPMENT
CONDITION:
WARNING
Smoking, open flame, sparks, and glowing or
hot objects are not allowed within 50 feet of
work area. Fuel may catch fire and explode,
causing injury to personnel and damage to
equipment.
Removal.
a.
FRAME 1
1.
Using wrenches, hold screw (1) and unscrew and take off nut (2) and
washer (3). Take out screw.
Take off manhole cover (5). Take off gasket (6)
2.
Take off clamp ring (4).
and throw it away.
END OF TASK
|