TM 9-2320-209-20-3-1
c.
Replacement.
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is being used. Use only
in well-ventilated places. If this is not done,
there may be injury to personnel and damage
to equipment.
FRAME 1
1.
Using dry cleaning solvent, clean surface of mounting flange on sending unit
(1) mounting flange and mating flange on fuel tank (2).
2.
Put gasket (3) on fuel tank (2) flange and aline five holes.
Carefully put float arm (4) into tank. Aline mounting holes in sending unit
3.
(1) with five holes in flange of fuel tank (2) as shown.
GO TO FRAME 2
|