TM 9-2320-209-20-3-1
c.
Replacement.
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in well
ventilated places. Failure to do this may result
in injury to personnel and damage to equipment.
FRAME 1
Put starter adapter gasket (1) over three studs (2) against mounting flange (3)
1.
Straight edge of gasket must be a right side.
2.
Before putting in starter, using solvent,
clean starter adapter (4) and
mounting flange of starter.
Put starter adapter (4) over three studs (2) against gasket (1).
3.
4.
Put starter gasket (5) over three studs (2) and against starter adapter (4).
Straight edge of gasket must be at right side as shown.
GO TO FRAME 2
|