TM 9-2320-209-20-3-1
c.
Replacement.
FRAME 1
I
1.
Put starter adapter gasket (1) over three studs (2) and against mounting
flange (3). Straight edge of gasket must be at bottom.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby
when solvent is used. Use only in well-ventilated
places. Failure to do this may result in injury to
personnel and damage to equipment.
2.
Before putting in starter, using solvent, clean starter adapter (4) of starter.
Put starter adapter (4) over three studs (2) and against starter adapter
3.
gasket (1).
4.
Put starter gasket (5) over three studs (2) and against starter adapter (4).
Straight edge of gasket must be at bottom as shown.
GO TO FRAME 2
|