FRAME 5
Push generator (1) toward engine and slip two V-belts (2) around pulley (3).
1.
NOTE
Do not hook up electrical connector to generator at this
time.  Polarization procedure must be done first.
Put lockwasher (4) and key washer (5) on bolt (6).
2.
Put bolt (6) through adjustment bracket (7), and screw bolt into generator
3.
flange (8) finger tight.
NOTE
Bolt (6) is not tightened until fan belt adjustment has
been done.
NOTE
Follow-on Maintenance Action Required:
1.
Adjust fan belt.  Refer to para 6-9.
2.
Do polarization procedure. Refer to para 7-3d.
3.
Start engine and check that battery-generator
indicator is in the green area.  Stop engine.
Refer to TM 9-2320-209-10.
4.
Close hood and right side panel. Refer to
TM 9-2320-209-10.
END OF TASK