TM 9-2320-209-20-3-1
Replacement.
c.
WARNING
Dry cleaning solvent is flammable, Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated area.
Failure to do this will result in injury to personnel
and damage to equipment.
NOTE
Clean thermostat housing (1) using solvent. Make
sure surfaces that meet hoses or gaskets are smooth
and clean.
Put seal (2) into thermostat housing (1) so that lip of seal faces outward
1.
toward thermostat (3).
2. Put thermostat (3) into thermostat housing (1) as shown.
GO TO FRAME 2