1-12. REPORTING IMPROVEMENT RECOMMENDATIONS .  If your truck needs im-
provement, let us know. Send us an EIR.  You, the user, are the only one who can
tell us what you don't like about your equipment.  Let us know why you don't like
the design.  Tell us why a procedure is hard to perform. Put it on an SF 368 (Quality
Deficiency Report). Mail it to us at:  Commander, U.S. Army Tank Automotive
Material Readiness Command, ATTN :  DRSTA-MT , Warren, Michigan 48090. We'll
send you a reply.
1-13. METRIC SYSTEM.  The equipment /system described herein is nonmetric and
does not require common or special tools.  Therefore, metric units are not supplied.
Tactical instructions, for sake of clarity, will also remain nonmetric.
1-14. DESTRUCTION TO PREVENT ENEMY USE.  Follow procedures given in
TM 750- 244-6 for destruction of Army material to prevent enemy use.
1-15.  VEHICLE DESCRIPTION .  For vehicle description refer to TM 9-2320-209-10.
1-16.  TABULATED DATA .  Data is detailed in subparagraphs a through j below for
the 2 1/2 ton, 6x6, series trucks.  Detailed data is the same for all models, except
as noted.
a.  Engine and Cooling System.
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.S. Army (LD-465-1,
LD-465-lC , LDT-465-lC)
Cylinders (in-line) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Brake horsepower (gross @ 2,600 rpm) . . . . . . . . . 140
Torque ( gross, minimum, pound-feet):
LD-465-1, LD-465-lC and
LDT-465-lC at 1,500 rpm) . . . . . . . . . . . . . . . . . . . 305
Ignition system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compression
Firing order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5-3 -6-2-4
Idle speed:
Except LDT-465-lC . . . . . . . . . . . . . . . . . . . . . . . . . . 650-700rpm
LDT-465-lC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800-850 rpm
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liquid
Radiator:
Ord No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10876110
Radiator filler cap:
Ord No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MS35840-1
Opening pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 61/2 to 8 psi
Opening vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 1/4 psi
Coolant capacity (quarts) . . . . . . . . . . . . . . . . . . . . . . 28-32
Thermostat
Ord No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10911114
Starts to open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180F
Fully opened . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200F
Compression radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22:1
Piston stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.87 in.
Fan and water pump drive belt (set of two
matched belts) :
Ord No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5702650
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Notched V
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 in.
Oil filters: 2
Ord No.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8748329