TM 9-6115-663-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-41, PU-805, and PU-806 (continued)
Location
Not Fully Mission
Item
Procedure
Capable if:
Item to Check/Service
Interval
No.
WARNING
enclosed areas unless exhaust is properly vented outside. Severe personal injury
or death due to carbon monoxide poisoning could result.
GENERATOR SET-
continued
Check muffler for evidence of
Muffler or exhaust
EXHAUST SYSTEM
24
Before
system damaged or
leakage and exhaust system for
leaking.
corrosion, damage or missing
parts.
Inspect air cleaner assembly (26)
Before
AIR CLEANER ASSEMBLY
Loose or damaged
25
and piping (27) for loose or
connections.
damaged connections.
Inspect restriction indicator (28)
Clogged element is
for clogged element. If indicator
indicated or piping
shows red, notify next higher level
and connections are
of maintenance.
loose.
2-20
|