TM 9-6115-663-13&P
Table 2-2. Operator Preventlve Maintenance Checks and Services
for AN/MJQ-41, PU-805, and PU-806 (continued)
Location
Not Fully Mission
Itern
Capable if:
Procedure
Item to Check/Service
Interval
No.
I
GENERATOR SET
MATERIALS Ensure that acoustical materials,
ACOUSTICAL
13
Before
located in the grill areas, are
secure, not damaged or missing.
WARNING
With any access door open, the noise level of this generator set could cause
hearing `damage. Hearing protection must be worn when working near the
generator set while working.
WARNING
The fuels used in this generator set are highly explosive. DO NOT smoke or use
open flame when performing maintenance. Flames and explosion can occur,
resulting in severe personal injury or death.
a . Visually inspect the generator
Any fuel leaks. Any
Before
14
ENGINE ASSEMBLY
Class III oil or
set for fuel, oil, and coolant
leaks. Check for proper ground coolant leaks.
connections.
b . Visually inspect the engine for
Any condition that
renders power
missing, loose, or damaged
unit/power plant not
parts and hardware, and for
mission capable.
unusual wear or deterioration.
DEAD CRANK switch to
NORMAL.
2-17
|