TM 9-2320-391-10
M1078A1 SERIES PREVENTIVE MAINTENANCE
0087 00
CHECKS AND SERVICES (PMCS) - Continued
Table 13. Preventive Maintenance Checks and Services (PMCS) - Weekly -
Model M1079A1 - Continued.
ITEM
INTERVAL
MAN-
ITEM
CREWMEMBER
EQUIPMENT
NO.
HOUR
TO BE
PROCEDURE
NOT READY/
CHECKED
AVAILABLE IF:
OR
SERVICED
3
Weekly
Electrical
2. Check six electrical
Three or more
Receptacles
receptacles (3) and
electrical
and Binding
binding posts (4) for
receptacles or
Posts -
obvious signs of
one or more
Continued
damage.
binding post(s)
are damaged.
4
Weekly
Power
1. Check 100/208
100/208 VAC
Distribution
VAC POWER
POWER
Panel
DISTRIBUTION PANEL
DISTRIBUTION
(5) for obvious signs
PANEL is
of damage.
damaged to the
extent that a
shock hazard is
present.
2. Stow ladder (WP
0087 00-151
|