TM 9-2320-391-10
M1078A1 SERIES PREVENTIVE MAINTENANCE
0087 00
CHECKS AND SERVICES (PMCS) - Continued
Table 4. Preventive Maintenance Checks and Services (PMCS) - Weekly -
All Models - Continued.
ITEM
INTERVAL
MAN-
ITEM
CREWMEMBER
EQUIPMENT NOT
NO.
HOUR
TO BE
PROCEDURE
READY/
CHECKED
AVAILABLE IF:
OR
SERVICED
6
Weekly
Batteries -
2. Check for
One or more
Continued
damaged casing,
batteries are
terminal posts
missing,
(33), and security
unserviceable, or
of mounting. Check
leaking. Battery
that cable clamps
cable clamps are
are secure. Notify
loose.
Field Maintenance
if defects are
found.
3. Check battery
fluid level (34) (WP
0092 00). If fluid
level is low, fill with
distilled water. If
fluid is gassing (to
boiling), notify Field
Maintenance.
0087 00-71
|