TM 9-2320-391-10
M1078A1 SERIES PREVENTIVE MAINTENANCE
0087 00
CHECKS AND SERVICES (PMCS) - Continued
Table 1. Preventive Maintenance Checks and Services (PMCS) - Before -
All Models - Continued.
ITEM
INTERVAL
MAN-
ITEM
CREWMEMBER
EQUIPMENT
NO.
HOUR
TO BE
PROCEDURE
NOT READY/
CHECKED
AVAILABLE
OR
IF:
SERVICED
NOTE
CREWMEMBER PROCEDURE 16 applies to vehicle S/N 18,549 or lower.
9
Before
Interior Cab
16. Check that
VOLTS gage
Components
VOLTS gage (41)
indicates more
- Continued
reads between 26
than 30 volts
and 30 volts.
or less than 26
volts.
NOTE
CREWMEMBER PROCEDURE 17 applies to vehicle S/N 18,550 or higher.
17. Press 12 V BAT
VOLTS gage
switch (42). Check
indicates more
that VOLTS gage
than 14 volts
(41) reads between
or less than 12
12 and 14 volts.
volts.