TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
139. STOPLIGHTS AND
5. If circuit breaker CB76 has
12 VDC
not tripped again, perform
INDICATOR PANEL
test 4 of this malfunction.
CIRCUITS DO NOT
OPERATE -
Continued
3. Check circuit breaker
1. Remove PDP cover (WP 0095
CB76 in PCB to see if
it is tripped.
2. Open PDM 2.
3. If circuit breaker CB76 has
tripped, push in to reset.
4. Position master power switch
to on (WP 0004 00).
5. If circuit breaker CB76 has
tripped again, contact
supervisor.
0069 00-141
|