TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
124. M1079A1
2. If emergency lights do
BLACKOUT
illuminate, notify Field
LIGHT(S) DOES
Maintenance.
NOT ILLUMINATE -
Continued
125. M1079A1
1. Check circuit
1. If either circuit breaker is
EMERGENCY
breakers CB10 and
tripped, push in to reset and
LIGHT(S) DOES
CB11 on relay box to
perform test 2 of this
NOT ILLUMINATE
see if it is tripped.
malfunction.
2. If circuit breakers are not
tripped, perform test 2 of this
malfunction.
2. Check to see if
1. If circuit breaker trips again,
emergency lights
notify Field Maintenance.
illuminate (WP 0031
2. If emergency lights do not
illuminate, perform test 3 of
this malfunction.