TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
106. ETHER STARTING
2. Check to see if ether
If ether cylinder is damaged,
AID DOES NOT
cylinder is damaged
notify Field Maintenance.
OPERATE -
(WP 0087 00, Table
Continued
5, Item 2).
3. Check to see if ether
If ether starting aid does not
starting aid operates
operate, perform Fuel System
Troubleshooting (WP 0066
Starting Aid Does Not
Operate).
107. RADIO DOES NOT
1. Check circuit breaker
1. Remove PDP cover (WP 0095
OPERATE
CB20 in PCB to see if
it is tripped.
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Position radio to on.
5. Position radio to off.
0069 00-104
|