ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
105. ENGINE FAN DOES
1. Check to see if air
1. Start engine (WP 0016 00).
NOT TURN OFF
tanks are
USING ENGINE
pressurized.
FAN OFF SWITCH
2. Allow engine to idle until 120
psi is registered on FRONT
BRAKE AIR and REAR BRAKE
AIR pressure gages.
3.  Shut down engine (WP 0016
4. If FRONT BRAKE AIR or REAR
BRAKE AIR pressure gage
does not register 120 psi,
perform Air System
Troubleshooting (WP 0074
00, Malfunction 1, Air System
Loses Pressure During
Operation/Slow Air Pressure
Buildup).
0069 00-101