ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
102. POWER TAKE-OFF
2. Check to see if PTO
If PTO does not engage,
(PTO) DOES NOT
engages (WP 0039
notify Field Maintenance.
ENGAGE -
Continued
103. ELECTRICAL
1. Has Preventative
1. If PMCS Before checks have
SYSTEM DOES
Maintenance Checks
not been performed, perform
NOT MAINTAIN A
and Services (PMCS)
M1078 A1 Series Preventative
CHARGE IN
Before checks been
Maintenance Checks and
BATTERIES /
performed?
Services (PMCS) (WP 0087
CHARGING
00) Before Checks.
SYSTEM
INDICATOR
ILLUMINATES
2. If PMCS Before checks have
been performed, go to test 2
of this malfunction.
2. Are batteries, battery
1. Remove battery box cover
cables, and terminal
post free from
damage and
corrosion?
0069 00-96