TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
95. CENTRAL TIRE
1. Check circuit breaker
1. Remove PDP cover (WP 0095
INFLATION
CB40 in PCB to see if
SYSTEM (CTIS)
it is tripped.
DOES NOT
OPERATE
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check circuit breaker to see if
it is tripped again. If circuit
breaker is tripped or trips
again, notify Field
Maintenance.
5. Position master power switch
to off (WP 0004 00).
6. Install PDP cover (WP 0095
0069 00-91
|