TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
92. HORN,
5. If audible alarm does not
WINDSHIELD
operate, perform Malfunction
WIPERS, AND
2 (24 VDC Circuits Do Not
WINDSHIELD
Operate).
WASHER DO NOT
6. If audible alarm operates, go
OPERATE -
to test 2 of this malfunction.
Continued
2. Is vehicle S/N 11,438
1. If vehicle S/N is 11,438 to
to 99,999?
99,999 go to test 3 of this
malfunction.
2. If vehicle S/N is not 11,438 to
99,999 go to test 4 of this
malfunction.
3. Is circuit breaker
1. Remove PDP cover (WP 0095
CB37 tripped?
2. If circuit breaker CB37 is
tripped, push in to reset.
3. Position master power switch
to on (WP 0004 00).
0069 00-87
|