ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
45. LAMP TEST 24 VDC
2. Check to see if lamp
If lamp test 24 VDC does not
DOES NOT
test 24 VDC operates
operate, notify Field
OPERATE -
Maintenance.
Continued
46. LAMP TEST
1. Do service drive
1. Position main light switch to
GROUND DOES
lights illuminate?
SER DRIVE (WP 0004 00).
NOT OPERATE
(Vehicle S/N
11,438 to 99,999)
2. Check to see if service drive
lights illuminate.
3. Position main light switch to
4. If service drive lights do not
illuminate, perform
Malfunction 3 (12 VDC
Circuits Do Not Operate (100
AMP Alternator)).
5. If service drive lights
illuminate, go to test 2 of this
malfunction.
2. Do stoplights
1. Position master power switch
illuminate?
NOTE
Lamp test ground and stoplights operate on same circuit.
2. Position main light switch to
STOPLIGHT (WP 0004 00).
3. Depress brake pedal.
4. Check to see if stoplights
illuminate.
5. Release brake pedal.
0069 00-54