ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
22. COOLANT TEMP
4. If WATER TEMP gage does
INDICATOR DOES
not operate, perform
NOT ILLUMINATE -
Malfunction 143 (24 VOLTS
Continued
Gage, OIL PRESS Gage,
WATER TEMP Gage, and
Speedometer Do Not
Operate).
5. If WATER TEMP gage
operates, notify Field
Maintenance.
23. COOLANT TEMP
Does WATER TEMP
1. Start engine (WP 0016 00).
INDICATOR
gage read below
ILLUMINATES
216F (102C) when
COOLANT TEMP
indicator illuminates?
2. Check to see if WATER TEMP
gage reads below 216F
(102C) when COOLANT
TEMP indicator illuminates.
3. If WATER TEMP gage reads
above 216F (102C) when
COOLANT TEMP indicator
illuminates, perform Cooling
System Troubleshooting (WP
0064 00, malfunction 1,
Engine Overheats).
4. If WATER TEMP gage reads
below 216F (102C) when
COOLANT TEMP indicator
illuminates, notify Field
Maintenance.
5. Shut down engine (WP 0016
0069 00-35