ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
14. AUDIBLE ALARM
3. Check to see if lamp
1. If lamp test switch does not
DOES NOT
test switch
illuminate lighted indicator
OPERATE -
illuminates lighted
display, perform Malfunction
Continued
indicator display (WP
46 (Lamp Test Ground Does
Not Operate).
2. If lamp test switch illuminates
lighted indicator display, go to
test 4 of this malfunction.
4. Do radio, electrical
1. Check to see if electrical
gages, and starter
gages and starter pushbutton
pushbutton operate?
1. If electrical gages and starter
pushbutton do not operate,
perform Malfunction 135
(Audible Alarm, Radio,
Electrical Gages, and Starter
Pushbutton Do Not Operate).
2. If electrical gages and starter
pushbutton operate, notify
Field Maintenance.
15. AUDIBLE ALARM
1. Check to see if lamp
1. If lamp test switch does not
DOES NOT
test switch
illuminate lighted indicator
OPERATE WHEN
illuminates lighted
display, go to test 3 of this
TROOP
indicator display (WP
malfunction.
TRANSPORT
ALARM SWITCH IS
TURNED ON
2. If lamp test switch illuminates
lighted indicator display, go to
test 2 of this malfunction.
2. Check to see if
1. Drain air tanks (WP 0016 00).
audible alarm sounds
from low air
pressure.
2. Position master power switch
0069 00-30