ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. OIL PRESS GAGE
2. If vehicle S/N is not 11,438 to
DOES NOT
99,999 go to test 4 of this
OPERATE OR IS
malfunction.
INACCURATE -
Continued
4. Does 24 VOLTS gage
1. Position master power switch
operate?
2. Check to see if 24 VOLTS
gage operates.
3. Position master power switch
4. If 24 VOLTS gage does not
operate, perform Malfunction
143 (24 VOLTS Gage, OIL
PRESS Gage, WATER TEMP
Gage, and Speedometer Do
Not Operate).
5. If 24 VOLTS gage operates,
notify Field Maintenance.
12. SPEEDOMETER
1. Do any instrument
1. Position master power switch
DOES NOT
panel gages operate?
OPERATE OR IS
INACCURATE
2. Check to see if any
instrument panel gages
operate.
3. Position master power switch
4. If no instrument panel gages
operate, perform Malfunction
134 (All Electrical Gages Do
Not Operate).
5. If any instrument panel gages
operate, go to test 2 of this
malfunction.
0069 00-27

Privacy Statement - Press Release - Copyright Information. - Contact Us