ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. REAR BRAKE AIR
2. Check to see if REAR
1. Start engine (WP 0016 00).
PRESSURE GAGE
BRAKE AIR pressure
DOES NOT
gage operates and is
OPERATE OR IS
accurate.
INACCURATE -
Continued
2. If REAR BRAKE AIR pressure
gage does not operate or is
inaccurate notify Field
Maintenance.
3. Shut down engine (WP 0016
10. FRONT BRAKE AIR
1. Check to see if any
1. Position master power switch
PRESSURE GAGE
instrument panel
DOES NOT
gages operate.
OPERATE OR IS
INACCURATE
2. If no instrument panel gages
operate, perform Malfunction
134 (All Electrical Gages Do
Not Operate).
3. Position master power switch
2. Check to see if
1. Start engine (WP 0016 00).
FRONT BRAKE AIR
pressure gage
operates and is
accurate.
2. If FRONT BRAKE AIR pressure
gage does not operate or is
inaccurate notify Field
Maintenance.
3. Shut down engine (WP 0016
0069 00-24