TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. FUEL GAGE DOES
2. Has Preventative
1. If PMCS Before checks have
NOT OPERATE OR
Maintenance Checks
not been performed, perform
IS INACCURATE -
and Services (PMCS)
PMCS Before checks.
Continued
Before checks been
performed?
2. If PMCS Before checks have
been performed, go to test 3
of this malfunction.
3. Check to see if any
1. Position master power switch
instrument panel
to on (WP 0004 00).
gages operate.
2. If no instrument panel gages
operate, perform Malfunction
134 (All Electrical Gages Do
Not Operate).
3. If fuel gage does not operate
or is inaccurate, notify Field
Maintenance.
4. Position master power switch
to off (WP 0004 00).
8. WATER TEMP
1. Check to see if any
1. Position master power switch
GAGE DOES NOT
instrument panel
to on (WP 0004 00).
OPERATE OR IS
gages operate.
INACCURATE
2. If no instrument panel gages
operate, perform Malfunction
134 (All Electrical Gages Do
Not Operate).
3. If WATER TEMP gage does
not operate or is inaccurate,
go to test 2 of this
malfunction.
4. Position master power switch
to off (WP 0004 00).
0069 00-22
|