TM 9-2320-391-10
M1079A1 VAN AC POWER
0029 00
CONNECTING/DISCONNECTING - Continued
CONNECT AC POWER - Continued
WARNING
Ground cable must be connected between the chassis and the
ground rod before power can be applied. Failure to comply may
result in injury or death to personnel or damage to equipment.
Ensure that ground cable terminal makes good metal-to-metal
contact with bare metal on van body. If required scrape contact
are clean of dirt, paint, or rust. Failure to comply may result in
injury or death to personnel or damage to equipment.
NOTE
If required, scrape contact area clean of dirt, paint, or rust to make good
contact with ground receptacle.
5.
Install ground cable (2) on ground receptacle (5) with nut (4).
6.
Position ground cable (2) on ground rod (1).
7.
Tighten nut (6) on ground cable (2).