TM 9-2320-386-24-1-2
0331 00
STE/ICE-R WIRING HARNESS REPLACEMENT (Contd)
NOTE
Vehicles may come equipped with a Leece-Neville or Prestolite
alternator. The STE/ICE-R wiring harness leads are connected to
negative and positive posts on either alternator.
17.
Install STE/ICE-R harness lead 770-N (12) and positive lead 2 (11) on stud (13) with new
lockwasher (10) and nut (9).
18.
Install STE/ICE-R harness lead 770-P (15) and ground (GND) lead (4) on alternator (14) with new
lockwasher (6) and screw (5). Tighten screw (5) 45-55 lb-in. (5-1-6.2 Nm).
NOTE
Perform steps 19 through 21 for Prestolite alternators only.
19.
Install plate (1) on alternator (14) with two new lockwashers (2) and screws (3). Tighten screws (3)
30-35 lb-in. (3.4-3.9 Nm).
20.
Pack cover plate (8) with sealing compound.
21.
Install cover plate (8) on alternator (14) with two new assembled-washer screws (7).
NOTE
Perform steps 22 and 23 for Leece-Neville alternators only.
22.
Pack cover plate (8) with sealing compound.
23.
Install cover plate (8) on alternator (14) with two new lockwashers (18) and screws (7).
24.
Connect STE/ICE-R plug lead 770-O (17) to Y-connector (16).
25.
Install STE/ICE-R terminal lead 770-T (22) on post (23) with new lockwasher (21) and nut (20).
26.
Install STE/ICE-R terminal lead 770-M (26) on post (27) with new lockwasher (25) and nut (24).
27.
Install STE/ICE-R terminal lead 770-S (30) on post (31) on starter solenoid (19) with new lockwasher (29)
and nut (28).