TM 9-2320-386-24-1-2
0330 00
FRONT WIRING HARNESS REPLACEMENT (Contd)
19.
Position clamp (16) on wiring harness (19) and install clamp (16) on under side of frame rail (14)
with screw (18) and new locknut (17).
20.
Install two ground (GND) leads (13) on frame rail (14) with two new lockwashers (12), screw (11),
and nut (15).
NOTE
Vehicles may come equipped with a Leece-Neville or Prestolite
alternator. The wiring harness leads are connected to negative and
positive posts on either alternator.
21.
Install positive lead 2 and STE/ICE-R harness lead 770-N (4) on alternator terminal post (9) with
new lockwasher (8) and nut (7). Tighten nut (7) 45-55 lb-in. (5.1-6.2 Nm).
NOTE
Sealing compound is used to prevent corrosion on terminal posts.
Ensure wires and terminals are clean before connections are made.
22.
Apply sealing compound to leads (4) and terminal post (9) on alternator (10).
NOTE
Perform step 23 for Prestolite alternator only.
23.
Install plate (1) on alternator (10) with two lockwashers (2) and screws (3). Tighten screws (3)
30-35 lb-in. (3.4-3.9 Nm).
24.
Pack cover plate (5) with sealing compound.
8