TM 9-2320-386-24-1-1
0281 00
AIR DRYER AND AIR DRYER HEATER MAINTENANCE (Contd)
NOTE
For schematic representation of air line locations and routing,
refer to WP 0386 00 of this manual.
AIR DRYER REMOVAL
WARNING
Do not disconnect air lines before draining air reservoirs. Small
parts under pressure may shoot out at high velocity, causing
injury to personnel.
Eyeshields must be worn when releasing compressed air. Failure
to do so may result in injury to personnel.
CAUTION
When disconnecting air lines and hoses, plug all openings to
prevent dirt from entering and causing damage to internal parts.
Remove all plugs prior to installation.
NOTE
Tag air lines for installation.
1.
Loosen nut (10) and remove tube (9) from air dryer outlet port elbow (11).
2.
Loosen nut (19) and remove tube (16) from air dryer control port elbow (12).
3.
Loosen nut (3) and remove tube (4) from air dryer inlet port elbow (8).
4.
Disconnect wire harness connector 27 (18) from air dryer heater connector (17).
5.
Remove nut (15), lockwasher (14), clamp (13), and jamnut (20) from clamp (1). Discard
lockwasher (14).
6.
Remove screw (6) and lockwasher (5) from air dryer (7) and mounting bracket (2). Discard
lockwasher (5).
7.
Remove air dryer (7) from clamp (1) and mounting bracket (2).