CHEMICAL AGENT ALARM MOUNTING KIT REPLACEMENT (Contd)
REMOVAL
1.
Remove nut (3) and harness receptacle (27) from bracket (2).
2.
Remove four locknuts (10), support (9), two screws (1) and (5), clamp (6), harness (7), and detector
unit bracket (4) from left front fender (8). Discard locknuts (10).
3.
Remove locknut (11), screw (26), clamp (12), and harness (7) from left front fender (8). Discard
locknut (11).
4.
Disconnect leads 25 (18), 25 (20), and lead 25 (21) from connector (19).
5.
Disconnect lead 25 (25) from connector (24).
6.
Remove locknut (14), lockwasher (15), screw (23), harness ground (GND) wire (22), ground
strap (17), and lockwasher (16) from right side of turn signal flasher box (13). Discard locknut (14)
and lockwashers (15) and (16).
7.
Remove four tiedown straps (36) from main wiring harness (35). Discard tiedown straps (36).
NOTE
Assistant will help with steps 8 through 14.
8.
Remove locknut (39), screw (38), and clamp (37) from firewall (34). Discard locknut (39).
9.
Remove two screws (42), clamps (43), and harness (7) from frame (44).
10.
Remove grommet (46) from cab floor hole (45).
11.
Remove screw (41) and clamp (47) from rear cab panel (29).
12.
Remove two locknuts (33), screws (30), and clamps (31) from alarm unit bracket (32). Discard
locknuts (33).
13.
Remove harness (7) from firewall (34), cab floor hole (45), and rear cab panel (29).
14.
Remove two locknuts (28), screws (40), and alarm unit bracket (32) from rear cab panel (29).
Discard locknuts (28).