PERSONNEL HEATER FUEL PUMP REPLACEMENT (Contd)
.WARNING.
Do not perform this procedure while smoking or near sparks or
open flame. Fuel is flammable and can explode easily, causing
injury or death to personnel and damage to equipment.
REMOVAL
1.
Disconnect wire (6) from wire 401 (5).
CAUTION
Cap or plug all hoses, connections, and openings immediately
after disconnection to prevent contamination. Remove caps or
plugs prior to installation. Failure to do so may result in damage
to equipment.
2.
Disconnect inlet line (3) from fuel pump (11).
3.
Disconnect outlet line (1) from elbow (2).
4.
Remove elbow (2) from fuel pump (11).
5.
Remove two screws (7), lockwashers (8), clamp (10), ground wire (9), and fuel pump (11) from
plate (4). Discard lockwashers (8).
INSTALLATION
1.
Apply sealant to male threads of elbow (2).
2.
Install fuel pump (11), ground wire (9), and clamp (10) on plate (4) with two new lockwashers (8)
and screws (7).
3.
Install elbow (2) on fuel pump (11).
4.
Connect outlet line (1) to elbow (2).
5.
Connect inlet line (3) to fuel pump (11).
6.
Connect wire (6) to wire 401 (5).
7.
Connect battery ground (GND) cable (WP 0121 00)
0249 00-2